Menu
Your Cart

MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand

MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
Built to order
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
MDE884RH - Fibre Array / Crystal Rotator, Long Reach, Right Hand
  • Stock: In stock - Contact us for lead times.
  • Click here to: Contact us
  • Model: Martock MDE884RH
£1,180.00

Fibre Array/Crystal Rotator, Long Reach, R/H   

MDE884RH   

  • θx fibre array / crystal manipulator
  • Rotates exactly on x-axis
  • Maintains 18 mm centre height
  • Right and Left handed versions available

This θx ribbon cable / crystal manipulator (long reach) has a unique roll mechanism to ensure rotation is exactly about the x-axis, at an 18 mm centre height. Right and left handed versions available. Can also be supplied with θy and θz adjustments.

The front block is machined by Elliot Scientific (or customer) to locate silicon V-groove block on the fibre (US: fiber) ribbon. Alternatively, it can be replaced by a device holder as shown in the photo below.

MD01/059 Left-hand and MD01/060 Right-hand Device Holders

MD01/059 Left-hand and MD01/060 Right-hand Device Holders
These can been ordered as a replacement for the existing MDE884 front block

The unique mechanical roll design features a decoupling of the linear adjuster travel from the roll motion, which minimises any radial offset during rotation. This ensures that angular movements are exactly about the x-axis and that no radial offset is introduced. The precision of motion results in a very high level of accuracy of the roll angle.

Specifications

ConfigurationLeft hand
Centre Height    Maintained at 18mm
θx RotationCoarse range± 4°
 Fine range± 10 arc minutes
θx ResolutionCoarse adjustment    8 arc seconds
 Fine adjustment< 0.1 arc seconds

 

MDE885 L/H and R/H units incorporated into a waveguide alignment system

 

Further options
θy and θz versions
Inverted drive version if space is limited

File NameSizeLink
MDE884_130.PDF115.13 kbDownload
MDE884_130.SLDPRT1.57 MbDownload
MDE884_130.STEP3.31 MbDownload
MDE884_3D_130.PDF1.62 MbDownload
Showing 1 to 4 of 4 (1 Pages)